MR Test
  • »óǰ°¡ (ºÎ°¡¼¼ º°µµ) 46,000¿ø

»óǰ¼±ÅÃ

      ÃÑ »óǰ ±Ý¾× 0 ¿ø

      »ó¼¼ Á¤º¸¸¦ È®´ëÇØ º¸½Ç ¼ö ÀÖ½À´Ï´Ù












       



      * Methyl-Red °Ë»ç¸¦ À§ÇÑ ¹Ì»ý¹° µ¿Á¤ ŰƮÀÔ´Ï´Ù.

      * ÇÏ´Ü °ü·ÃÁ¦Ç° ½ÇÇèÇϱ⠹öưÀ» Ŭ¸¯ÇÏ½Ã¸é ½ÇÇè¹æ¹ý¿¡ ´ëÇÑ ³»¿ëÀ» È®ÀÎÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.

       

       

       

      MR Test [MB-MR-100]




       

       

       

      Methyl-Red solution for Methyl-Red test.

       

      PACKAGE

       

      Description

      Quantity

      Cat. No

      Methyl-Red Reagent

      5 x 10 ml

      MB-MR-100

      MR-VP Broth

      (º°µµ ±¸¸Å ÇÊ¿ä)

      500g

      MB-M1032

       

       

       

      INTERPRETATION OF THE RESULTS

       

      Color of medium

      MR Test

      Red

      Positive

      Yellow

      Negative

       

       

       

      QUALITY CONTROL FOR USE

       

      Quality control microorganism

      Microorganism

      ATCC

      MR Test

      Escherichia coli

      25922

      +

      Klebsiella pneumonia

      13883

      -

       

       

       

      PRINCIPLE OF THE METHOD

       

      Dextrose¸¦ ¹ßÈ¿ÇÏ´Â ¹Ì»ý¹°À» °ËÃâÇÏ´Â ½ÃÇèÀ̸ç, °í³óµµ »êÀ¸·Î ¹ßÈ¿ÇÏ´Â Àå³» ¼¼±ÕÀ» ½Äº°Çϱâ À§ÇØ »ç¿ëµË´Ï´Ù. ¸ðµç Àå³» ¼¼±ÕÀº óÀ½¿¡ Dextrose ´ë»ç¿¡¼­ ÇÇ·çºê»êÀ» »ý¼ºÇÏÁö¸¸ ÀϺΠÀå³» ¼¼±ÕÀº ÀÌÈÄ È¥ÇÕ»ê °æ·Î¸¦ »ç¿ëÇÏ¿© ÇÇ·çºê»êÀ» ´Ù¸¥ »ê(Á¥»ê, ¾Æ¼¼Æ®»ê ¹× Æ÷¸§»ê)À¸·Î ´ë»çÇÕ´Ï´Ù. ÀÌ·¯ÇÑ ¹ÚÅ׸®¾Æ¸¦ MR ¾ç¼ºÀ¸·Î ºÐ·ùÇϰí, ´Ù¸¥ Àå³» ¼¼±ÕÀº ÀÌÈÄ ºÎÆ¿·» ±Û¸®ÄÝ °æ·Î¸¦ »ç¿ëÇÏ¿© ÇǸ£ºÎ»êÀ» Áß¼º ÃÖÁ¾ »ê¹°ÀÎ ¾Æ¼¼ÅäÀÎ, ºÎźµð¿Ã µîÀ¸·Î ´ë»çÇÕ´Ï´Ù. ÀÌ·¯ÇÑ ¹ÚÅ׸®¾Æ¸¦ MR À½¼ºÀ¸·Î ºÐ·ùÇÕ´Ï´Ù.

       

       

       

      PROCEDURE

       

      MR-VP Broth [MB-M1032] ¹èÁö¸¦ Á¦Á¶ÇÏ¿© 5mLÀÇ ¹èÁö¿¡ ¼ø¼ö¹è¾çÇÑ ÀǽÉÁý¶ôÀ» Àß Ç®¾îÁÝ´Ï´Ù.

      36¡¾1¡É¿¡¼­ 48½Ã°£¿¡¼­ ÃÖ´ë 72½Ã°£±îÁö ¹è¾çÇÕ´Ï´Ù.

      • ¹è¾ç¾×¿¡ MR ½Ã¾à 5¹æ¿ïÀ» ÷°¡ÇÕ´Ï´Ù.

      • »ö»óÀÇ º¯È­¸¦ °üÂûÇÕ´Ï´Ù.

       

       

       

      STORE

       

      Keep MR Test at 2-6¡ÆC in their original packaging protected from sunlight. Keep them away from sources of heat and avoid excessive temperature fluctuations. In these conditions, MR Test are valid until the expiry date shown on the label. Do not use them beyond expiry date. Dispose of them if they show signs of deterioration.